INOWA "System H-C2"

The separator in oval design with enlarged sludge trap.

INOWA
The separator in oval design with enlarged sludge trap
System designation: INOWA "SYSTEM H-C2"
Design: Filterless high-performance separator in compact construction for underground installation
Construction: Monolithic reinforced concrete basin, oval construction

Tested and CE-marked according to EN 858-1
fulfils the requirements according to DIN 1999-100 and DIN 1999-101 registered according to ÖNORM B5101

INOWA – The Nr. 1 in maintenance-free separation technology
  • All the advantages of the filterless high performance
    INOWA "System H" separator
  • High performance separator with enlarged sludge trap volumes in a monolithic reinforced concrete vessel
  • High nominal capacity with integrated sludge trap in a monolithic reinforced concrete vessel
Optional:
  • PEHD inliner instead of conventional coating

Typical applications:

High performance separator with enlarged sludge trap and increased sedimentation rate for applications with larger quantities of sludge, such as for:
  • Self-service wash bays
  • Wash bays for construction vehicles and machines
  • Wash bays for farm and forestry vehicles
  • Earthmoving equipment
  • Military vehicles, etc.
High performance separator with higher hydraulic loading in single basin version for applications such as surface drainage at:
  • Transport companies
  • Scrap yards
  • Accident-damaged vehicle parking areas
  • Airports, etc.
The separator in oval design with enlarged sludge trap.
The separator in oval design with enlarged sludge trap

Nominal Size
      (l/s)
Oil storage
tank (liters)
shaft dimension
       (mm)
     minimum
square shaft
     (mm)
   minimum
inflow/outflow
      (mm)
Art. no.

Data sheets
       40      4003.200x2.500       300 H+ NS40
       50      5003.500x2.500       300 H+ NS50
       60      6004.000x2.500       300 H+ NS60
       70      7004.000x2.500       300 H+ NS70
       80      800       300 H+ NS80
      100     10005.900x2.500       400 H+ NS100

Specification texts are available on request.


LEGEND: INOWA "System H-C2"


NS      nominal size in l/s
SF       sludge trap in l
LxW    basin dimensions (length x width)
H        overall height of basin (incl. flat cover)
TZ       standard inflow depth
T         inflow depth to be specified by customer
DN     diameter connections 
DiBt   approved by 6-48

Contact us!